PC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19
  • PC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19
  • PC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19
  • PC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19
  • PC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19
  • PC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19

APC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19

APC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19, Metered, Metered-by-outlet, Switched, 0U, Vertical, Black, 24 AC outlet(s), C13 coupler, C19 coupler
In Stock
Reference: AP8659
Technical Headlines
  • Metered, Metered-by-outlet, Switched 0U Black
  • 24 AC outlet(s) C13 coupler, C19 coupler
  • 3680 W


APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets Power sequencing delays allow users to define the order in which to power up or down attached equipment Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding Current metering provides real-time remote monitoring of connected loads Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles User-defined alarms warn of potential circuit overloads before critical IT failures occur Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager
APC
AP8659

Data sheet

AC input frequency
50 - 60 Hz
AC outlet types
C13 coupler, C19 coupler
AC outlets quantity
24 AC outlet(s)
Certification
EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, PSE, UL, VCCI A, VDE
Depth
51 mm
Height
990mm
Load capacity
9200 VA
Maximum current
96 A
Maximum input current per phase
63 A
Maximum total current draw per phase
400 A
Monitoring
Humidity,Temperature
Mounting
Yes
Nominal input voltage
83 - 159 VAC
Nominal output voltage
200-230 V
Non-operating altitude
9144 m
Operating altitude
914.4 - 2133 m
Operating temperature (T-T)
8 - 35 °C
Package weight
998 g
Package width
985.6 mm
Rack capacity
9U
Storage temperature (T-T)
8 - 85 °C
Weight
VFD and cable: 36.6 lb; Pole (each): 50.7 oz; Base: 66.1 lb (VFD and cable: 1.29 lb; Pole (each): 1.79 oz; Base: 2.33 lb)
Width
993 mm
Product colour
White,Black

Specific References

EAN13
0731304299509

Similar products