APC APDU10450SM

3 phase, PDU, 240 V, 0U, 1.8 m, Black
In Stock
Reference: apdu10450sm
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server
and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power
metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can
be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum
outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or
labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating
phase design whereby each of the 3 phases are organized into small outlet groups which alternate
from top to bottom of the PDU to facilitate better power cord management and promote better load
balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network
Management Card to continue functioning in the event of an AC power loss. No interruption in Network
communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC)
which can be replaced without powering down the PDU or connected devices to minimize downtime
in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full
load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to
enhance and standardize network connectivity across all assets in the data center. A second ethernet
port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or
provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU
Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most
precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor
ports allow for optional sensors (sold separately) to be connected. For data center deployments across
multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to
simplify and standardize deployment.
APC

Data sheet

AC input frequency
50 - 60 Hz
AC outlet types
C13 coupler,C15 coupler,C19 coupler,C21 coupler
AC outlets quantity
42 AC outlet(s)
Cable length
1.8 m
Certification
UL 62368-1
CSA C22.2 No 62368-1
FCC part 15 subpart B
CE
EN 62368-1
Height
182.6 mm
Maximum current
60 A
Mounting
vertical
Nominal input voltage
200 - 240, 346 - 415 V
Non-operating altitude
0 - 15240 m
Operating altitude
914.4 - 2133 m
Operating relative humidity (H-H)
5 - 95 %
Operating temperature (T-T)
23 - 140 °F
Package height
1980 mm
Package weight
15700 g
Package width
132 mm
PDU types
Metered
Rack capacity
0U
Source data-sheet
Icecat.biz
Storage relative humidity (H-H)
5 - 95 %
Storage temperature (T-T)
-25 - 65 °C
Type
ZIP
Weight
12700 g
Width
5.6 mm
Product colour
Black